| Response Time |
|
<30
milliseconds |
|
| Indicators |
|
Run = Green LED
Stop = Red LED
Mat Status = 4 Mat Activated Red LEDs; 4 Mat
Disconnected Yellow LEDs
Relay Fault = Internal Yellow LED |
|
Operational
Modes |
|
Selectable automatic restart and guard only
modes |
|
| Power Input |
|
120 VAC (for 60 Hz), 240 VAC (for 50 Hz) or 24
VDC |
|
| Rated Supply Current |
|
0.125 A AC, 0.75 A DC |
|
| Safety Inputs |
|
Screw clamp connections for up to four 4-wire
safety mats with up to 40' cord length each (quick
disconnect mat connections also available) |
|
Safety Output
Relays |
|
Two captive contact relays with two closed
when run (NO) and one open when run (NC) sets of
contacts rated 8 amps at 230 VAC |
|
| Replaceable Relay Pack Life |
|
Mechanical: 10,000,000 operations
Electrical: 500,000 operations at 1 amp at 240 VAC |
|
Electrostatic
Discharge (ESD) |
|
+/- 10kV (air
discharge)
+/- 6kV (contact discharge) |
|
| Radiated RF Field |
|
10 volts/meter,
100 to 1,000 MHz |
|
Electrical Fast
Transients (EFT) |
|
+/- 1kV (power
supply)
+/- 0.5kV (control signals) |
|
| Restart Function |
|
Selectable manual or automatic restart
Internal/Lockout restart and external/remote
restart available |
|
| Reset Function |
|
Power-up and Relay Fault Reset internal manual
pushbutton |
|
| Enclosure |
|
Steel (Powdercoat Machinery Black)
8" H x 6" W x 3.75" D
(203 mm x 152 mm x 95 mm) |
|
| Enclosure Rating |
|
NEMA 12, IP 65 |
|
| Mounting |
|
Surface Mount |
|
| Shipping Wt. |
|
11 lbs |
|
Operating
Temperature |
|
32 F to 121 F
(0 C to 50 C) |
|
| Relative Humidity |
|
Acceptable Range = 20-90% |
|
| Standards of
Conformity |
|
Designed to meet UL 508-1999 Standard for
Industrial Control Equipment, ANSI B11.19-2003
Performance Criteria for Safeguarding, OSHA
1910.212-1996 General Machine Guarding, ANSI/RIA
15.06-1999 Industrial Robots and Robots
Systems-Safety Requirements, EN/IEC 60204-1998
Electric Equipment of Machines and EN 1760-1-1998
Safety of Machinery, Pressure Sensitive Protective
Devices |